CAA-100B

  • Name:
  • CAA-100B
  • Model:
  • CAA-100B
  • Specifications:
  • Brand:
  • Product Code:
  • Color:
  • Price:
  • Clicks:
  • 272
  • Date:
  • 2018-07-19 17:35:55
  • Clicks:
  • Documents:
    Details

      CAA-100B Cable & Antenna Analyzer                                                       User Manual Download

      ShinewayTech® CAA-100 cable & antenna analyzer can test Return Loss and VSWR of load’ frequency. Also can get Return Loss, VSWR of DTF (distance-to-fault) and Cable Loss. Users can be easy to know the connection of cable & antenna system is reliable whether or not. CAA-100 series with frequency range 1MHz - 6GHz and 60dB dynamic range can suitable for 2G/3G/4G/5G/WiFi system etc. CAA-100 series are the necessary measuring instrument for the new generation of wireless network development, upgrade and maintenance.

    Features

       Frequency range: 1MHz to 6GHz ; suitable for 2G/3G/4G/WiFi system etc.

       Dynamic Rang up to 60dB

        Intelligent limit /marker /curve calculations

        More than 8 hours long battery life

    ●    7 inch color LCD touch screen

        Optimized batch file management: edit/delete/filter

        Excellent Man-Machine interface for easy operation

    Functions

    1.Multiple Standard measurement mode

    Spectrum, Power meter, Distance-to-fault (DTF) Return Loss, DTF Voltage Standing Wave Ratio (VSWR), Frequency Return Loss, Frequency VSWR and Cable Loss testing. Main interface  designs beautifully, user operation is convenient.

     

    2.Optional Power Meter

    USB high-precision power meter probe not only can connect the instrument to test and display the power, but also can connect the PC to analysis the result, which is greatly satisfy user.

    Terminating power meter and In Line Digital Power Meter can test a variety of signal, which can meet the demand of different level users.

    3.Intelligent analysis and judgment the trace

    CAA-100A series can analyze single or multi-segment limit line, marker and the curve calculation accurately.

    4.Convenient and precise calibrator: 1-port “T-type” Calibration Kit & ECAL Electronic calibrator

    It can calibrate precisely and conveniently. When the calibrated data points decrease, it is no need to recalibrate, which will increase the service efficiency.

    Electronic calibrator ECAL provides consistent calibration results, and removal the possible error of manual calibration.

    5.Instant switching the Return Loss and VSWR

    CAA-100A Cable and Antenna analyzer function can test the return loss and VSWR simultaneously, and switch the result instantly.

    6.Optimized batch file management function

    CAA-100A series file filter function is easy to implement batch editing and analysis the results.

    7. Field calibration cable and obtaining the parameters

    CAA-100A series can supply user input the cable parameters (propagation velocity, cable loss) or choose a known cable type. If user knows nothing about the cable parameters, he can make a field calibration by the equipment cable Calibration tool to get the accurate cable parameters.

    8.Manually set frequency or select the preset frequency

    According to the demand, it is convenient for user to manually set or select the preset frequency.

    9. Smith Phase Testing



    10. Energy saving, environmental protection and human interface design

    CAA-100 series is low-power designing, has high- capacity rechargeable lithium battery and AC adapter dual power supply, and more than 8 hours of continuous battery operation. The shortcut keys can set up four display modes: normal, black and white, highlight and night vision for different ambient.

    11.CAA Workbench PC software

    (1) Data Management Function

    ● Uploading and downloading files between the CAA-100a host and PC

      Interact files with PC, including open the local file and save the file to the local

    ● Support report print preview and print. Fully display the information such as company name, test parameters and measuring time etc.

    (2) Application Tools Function

      Distance-To-Fault

      Transform into Smith Chart

      Calculator

      Edit Signal Standard

      Edit Cable Parameter

    (3)Data Analysis

      Marker

      Limit line

      Scale

     Switching the Return Loss and VSWR

    Specifications

    Model

    CAA-100A

    Cable & Antenna Analyzer Function

    Frequency Range

    1-6000MHz

    Frequency Resolution

    1kHz

    Frequency Accuracy

    ±2ppm

    Output Power

    0dBm (typ.)

    Measurement Speed

    1.5ms/pt

    Data Points

    137,275,551,1103,2207,3310

    Directivity

    42dB (after calibration)

    Anti-jamming Capability

    17dBm@ Channel-5dBm@ Frequency

    Frequency

    Return Loss Range

    0-60dB

    Return Loss Resolution

    0.01dB

    VSWR Range

    1-65

    VSWR Resolution

    0.01

    Cable Loss Range

    0-30dB

    Cable Loss Resolution

    0.01dB

    Distance-to-Fault

    Distance-to-Fault Return loss Range

    0-60dB

    Distance-to-Fault VSWR Range

    1-65dB

    Measuring Range

    1500 m

    Resolution Ratio

    1.5*10^8*Vp/(F2-F1)  Vp: the cable's relative propagation velocity; F1/F2: start/stop frequency

    Phase

    Measuring Range

    -180° to +180°

    Resolution

    0.01°

    Smith

    Resolution

    0.01

    Spectrum Analyzer Function

    Frequency

    Frequency Range

    300-4000MHz

    Frequency Resolution

    1kHz

    Frequency Accuracy

    ±2.5ppm

    Frequency span

    1-3700MHz

    Resolution Bandwidth (RBW)

    1k-300kHz(1,3,10 step)

    Video Bandwidth (VBW)

    1k-300kHz(1,3,10 step)

    RBW/VBW

    1,3,10

    Amplitude

    Attenuator Range

    30dB

    Attenuator Step

    5dB

    Max. Continuous Input

    +26dBm

    Third-Order Intercept

    >+15dBm (typ.)

    Second harmonic distortion

    <-70dBc

    Displayed Average Noise Level(DANL)

    <-130dBm/Hz

    Measurement Accuracy

    ±1.5dB@25±5℃ (typ.)

    SSB Phase Noise @1GHz

    -85dBc/Hz @ 10kHz  offset;-120dBc/Hz @ 1MHz  offset

    Residual Spurious

    <-85dBm

    Display

    Dynamic Range

    <=100dB

    Measurement Range

    DANL to 20dBm

    Reference Level Range

    -80dBm - 30dBm

    Amplitude Units

    Logarithmically (dBm,dBv,dBmv,dBuv)

    Detection

    Sample, Peak, Negative, RMS, Standard

    Triggers

    Free Run, Video,

    VSWR

    2.2:1(typ.)

    General Information

    Connector Type

    N - Type female

    Input Impedance

    50 Ohm

    Display

    7 inch resistor touch screen, resolution 800×480

    Data Interface

    1USB Host Port,

    1USB Device Port,

    110M/100M Adaptive LAN Port

    Memory Space

    >2000 traces

    Language

    Chinese, English, Spanish

    Internal Battery

    11.1V 7800 mAh Rechargeable Lithium Battery

    External Adapter

    110 - 240V, 50 - 60Hz, AC input; 16V, 3.75A, DC output

    Operating Temp. Range

    -10℃ - 50℃

    Storage Temp. Range

    -40℃ - 70℃

    Humidity

    0 - 85% (Non-Condensing)

    Weight

    2.5kg

    Dimensions (L x W x H)

    290×175×75 mm

    TPM Module (Optional)--RF Terminal Power Meter

    Frequency Range

    50 - 4000MHz

    Power Range

    -40 - 20 dBm

    Maximum Power 

    <23 dBm

    Measure Uncertainty

    ≤±0.3db (15 - 35)≤±0.5dB( 0 - 50)

    Input VSWR

    <1.2

    Burst Width

    1µs - 60ms

    Min Repetition Period

    15Hz

    Video Band

    5MHz

    Minimum Pulse Width

    200ns

    Time Resolution

    0.1µs,1µs,15µs,150µs

    Peak Average Ratio

    <12dB

    CCDF Range

    0.1% - 100%

    CCDF Uncertainty

    ±3%

    Duty cycle

    0.1% - 100%

    Power Supply

    USB

    Operating Temp. Range

    0 - 50

    Storage Temp. Range

    -20 - 70

    Humidity

    0 - 85% (Non-Condensing)

    Weight

    0.3kg

    Dimensions (L x W x H)

    125×45×35mm

    DPM Module (Optional)--RF In Line Digital Power Meter

    Average Power Measurement

    Frequency Range

    300-4200MHz

    Power Range

    100mW-200W

    Dynamic Range

    ≥33 dB

    Insertion Loss

    ≤0.1 dB

    VSWR

    1.05 to 99.9

    Directivity

    ≥30 (<3GHz); ≥28 (>3GHz)

    Accuracy

    ±4%+0.05W(0 - +15 or +35 - +50 increase 3%)

    Impedance

    50Ω

    Connector

    N (Female)

    Data Interface

    USB

    Peak Power Measurement

    Peak Power Range

    100mW to 500W

    Peak Power Accuracy

    Burst width >200us: ±7%;

    1us<Burst width< 200us: ±10%;

    0.5us<Burst width< 1us: ±15%;

    Burst width< 0.5us: ±20%;

    Peak Average Ratio

    0 to12dB

    CCDF

    Measurement Range

    0.1 to 100%

    Measurement Accuracy

    ±3%

    Threshold Measurement Range

    0.05W to 500W

    Burst Power

    Burst Power Range

    100mW to 200W

    Burst Width

    1us to 60ms

    Min. Measurement Frequency

    15Hz

    Measurement Accuracy

    ±6% +0.05W

    Duty Cycle

    0.0001 to 1

     Others

    Power Supply

    USB

    Operating Temperature

    -10℃ to 50℃

    Storage Temperature

    -20℃ to70℃

    Relative Humidity

    0 to 85% (Non-condensing)

    Weight

    0.48kg

    Dimensions (H×W×T)

    130××124×34mm

    * Specifications subject to change without notice

    Order Information

    Standard Package:

    CAA-100 Host, Lithium Battery, AC Adapter, CD(PC Software, User Manual), Carrying Case, T-type Calibration Kits, Quick Reference, Warranty card

    Optional:

    ¨  TPM Module (Optional)--RF Terminal Power Meter

    ¨  DPM Module(Optional)—RF In Line Digital Power Meter

    Test Cables

    o  1.5m, N(m)-N(f), DC to 6GHz, 50 Ohm

    o  1.5m, N(m)-N(m), DC to 6GHz, 50 Ohm

    o  1.5m, N(m)-7/16 DIN(f), DC to 6GHz, 50 Ohm

    o  1.5m, N(m)-7/16 DIN(m), DC to 6GHz, 50 Ohm

    o  3m, N(m)-N(f), DC to 6GHz, 50 Ohm

    o  3m, N(m)-N(m), DC to 6GHz, 50 Ohm

    Adapters

    o  SMA(m)-N(m), DC to 6GHz, 50 Ohm

    o  SMA(f)-N(m), DC to 6GHz, 50 Ohm

    o  SMA(m)-N(f), DC to 6GHz, 50 Ohm

    o  SMA(f)-N(f), DC to 6GHz, 50 Ohm

    o  BNC(f)-N(m), DC to 6GHz, 50 Ohm

    o  7/16 DIN(f)-N(m), DC to 6GHz, 50 Ohm

    o  7/16 DIN(f)-N(f), DC to 6GHz, 50 Ohm

    o  7/16 DIN(m)-N(m), DC to 6GHz, 50 Ohm

    o  7/16 DIN(m)-N(f), DC to 6GHz, 50 Ohm

    o  7/16 DIN(m)-7/16DIN(m), DC to 6GHz, 50 Ohm

    o  7/16 DIN(f)-7/16DIN(f), DC to 6GHz, 50 Ohm

    o  N(m)-N(m), DC to 6GHz, 50 Ohm

    o  N(f)-N(f), DC to 6GHz, 50 Ohm

    o  N(m) 50Ohm – N(f) 75OhmDC to 3GHz

    o  N(f) 50Ohm – N(m) 75OhmDC to 3GHz

    Calibrators



All Products     |     Close

      All Products     |     Close