CAA-100

  • Name:
  • CAA-100
  • Model:
  • CAA-100
  • Specifications:
  • Brand:
  • Product Code:
  • Color:
  • Price:
  • Clicks:
  • 2923
  • Date:
  • 2014-09-14 23:36:35
  • Clicks:
  • Documents:
  • http://www.shinewaytech.com/admin/./up/1521451091.pdf
    Details

     CAA-100 Cable & Antenna Analyzer                                                                                                   User Manual Download

    ShinewayTech® CAA-100 cable & antenna analyzer can test Return Loss and VSWR of load’ frequency. Also can get Return Loss, VSWR of DTF (distance-to-fault) and Cable Loss. Users can be easy to know the connection of cable & antenna system is reliable whether or not. CAA-100 series with frequency range 25MHz-4GHz and 60dB dynamic range can suitable for 2G/3G/4G/WiMAX system etc. CAA-100 series is the necessary measuring instrument for the new generation of wireless network development, upgrade and maintenance.    

    Features

    ●  Frequency range:1MHz to 6GHz; suitable for 2G/3G/4G/WiMAX system etc.

    ●  Dynamic Rang up to 60dB

    ●  Intelligent limit /marker /curve calculations

    ●  More than 8 hours long battery life

    ●  7 inch color LCD touch screen

    ●  Optimized batch file management: edit/delete/filter

    ●  Excellent Man-Machine interface for easy operation

    Functions

    1.Five Standard measurement mode

    Distance-to-fault (DTF) Return LossDTF Voltage Standing Wave Ratio (VSWR)Frequency Return LossFrequency VSWR and Cable Loss testing. Main interface  designs beautiful, user operation is convenient.

    2.Optional

    USB high-precision power meter probe not only can connect the instrument to test and display the power, but also can connect the PC to analysis the result, which is greatly satisfy user.

    Terminating power meter and In-Line digital frequency spectrum power meter can test a variety of signal, which can meet the demand of different level users.

    3.Intelligent analysis and judgment the trace

    CAA-100 series can analyze single or multi-segment limit line, marker and the curve calculation accurately.

    4. Convenient and precise calibrator: 1-port , and “T-type” Calibration Kit

    It can calibrate precisely and conveniently. When the calibrated data points decrease, it is no need to recalibrate, which will increase the service efficiency.Electronic calibrator ECAL provides consistent calibration results, and removal the possible error of manual calibration.

    5.Instant switching the Return Loss and VSWR

    CAA-100 series can test the return loss and VSWR simultaneously, and switch the result instantly.

    6.Optimized batch file management function

    CAA-100 series file filter function is easy to implement batch editing and analysis the results.

    7 Field calibration cable and obtaining the parameters

    CAA-100 series can supply user input the cable parameters(propagation velocity, cable loss) or choose a known cable type. If user knows nothing about the cable parameters, he can make a field calibration by the equipment cable Calibration tool to get the accurate cable parameters.

    8.Manually set frequency or select the preset frequency

    According to the demand, it is convenient for user to manually set or select the preset frequency.

    9. Energy saving, environmental protection and human interface design

    CAA-100 series is low-power designing, has high-capacity rechargeable lithium battery and AC adapter dual power supply, and more than 8 hours of continuous battery operation. The shortcut keys can set up four display modes: normal, black and white, highlight and night vision for different ambient.

    10.CAA Workbench PC software

    (1) Data Management Function

      Uploading and downloading files between the CAA-100 host and PC

      Interact files with PC, including open the local file and save the file to the local

      Support report print preview and print. Fully display the information such as company name, test parameters and measuring time etc.

    (2) Application Tools Function

      Distance-To-Fault

      Transform into Smith Chart

      Calculator

      Edit Signal Standard

      Edit Cable Parameter

    (3) Data Analysis

      Marker

      Limit line

      Scale

      Switching the Return Loss and VSWR

    Specifications

    Model                        

    CAA-100

    Frequency Range 

    25MHz - 4000MHz

    Frequency Resolution

    100kHz

    Frequency Accuracy

    ±25ppm

    Output Power

    0dBm(typ.)

    Measurement Speed 

    3.5ms/point

    Data Points

    137, 251, 551, 1103

    Anti-jamming Capability

    Frequency

    -5dBm

    Channel

    +17dBm

    Directivity

    42dB (after calibration)

    Return Loss

    Return Loss Range

    0 - 60 dB

    Return Loss Resolution

    0.01dB

    VSWR

    VSWR Range 

    1 - 65

    VSWR Resolution

    0.01

    Cable Loss

    Cable Loss Range

    0 - 30dB

    Cable Loss Resolution

    0.01dB

    Distance-to-Fault

    Distance-to-Fault Return loss Range

    0 - 60 dB

    Distance-to-Fault SWR Range

    1 - 65 

    Measuring Length 

    1500m

    Resolution Ratio

    ( 1.5×108 ) × (Vp) / (F2-F1

    Where Vp is the cable's relative propagation velocity.

    where F2 is the stop frequency and F1 is start frequency

    Data Points

    137, 251, 551, 1103

    General Information

    Connector Type

    N-Type female

    Input Impedance

    50 Ohm

    Display

    7 inch resistor touch screen, resolution 800×480

    Data Interface

    One USB Host Port

    One USB Device Port

    One 10M/100M Adaptive LAN Port

    Memory Space

    >2000 traces

    Internal Battery

    11.1V 7800mAh Rechargeable Lithium Battery

    External Adapter

    110 - 240V, 50 - 60Hz, AC input; 16V, 3.75A, DC output

    Operating Temp. Range

    10 - +50 °C

    Storage Temp. Range

    40 - +70

    Humidity

    0 - 85% (Non-Condensing)

    Weight

    2.5kg (Suttle)

    Dimensions (L x W x H)

    290×175×75mm 

    TPM Module (Optional)--RF Terminal Power Meter

    Frequency Range 

    50 - 4000MHz

    Power Range 

    -40 - 20 dBm

    Maximum Power 

    <23 dBm

    Measure Uncertainty

    ≤ +/-0.3dB (15 - 35)

    ≤ +/-0.5dB( 0 - 50)

    Input VSWR

    <1.2

    Burst Width

    1µs - 60ms

    Min Repetition Period

    15Hz

    Video Band

    5MHz

    Minimum Pulse Width

    200ns

    Time Resolution

    0.1µs,1µs,15µs,150µs 

    Peak Average Ratio

    <12dB

    CCDF Range

    0.1% - 100%

    CCDF Uncertainty

    ±3%

    Duty cycle

    0.1% - 100%

    Power Supply

    USB

    Operating Temp. Range

    0 - 50

    Storage Temp. Range

    -20 - 70

    Humidity

    0 - 85% (Non-Condensing)

    Weight

    0.3kg

    Dimensions (L x W x H)

    105(125)×45×35mm

    Anti-vibration properties

    Conform to MIL-PRF-28800F class 3

    Elect. Compatibility Characteristics

    Conform to EMC GB/T 18268-2000

    DPM Module(Optional)RF In Line Digital Power Meter

    Average Power Measurement

    Frequency Range

    300-4200MHz

    Power Range

    100mW-200W

    Dynamic Range

    33 dB

    Insertion Loss

    0.1 dB

    VSWR

    1.05 to 99.9

    Directivity

    30 (<3GHz); 28 (>3GHz)

    Accuracy

    ±4%

    Impedance

    50Ω

    Connector

    N (Female)

    Data Interface

    USB

    Peak Power Measurement

    Peak Power Range

    100mW to 500W

    Peak Power Accuracy

    Burst width >200us: ±7%;

    1us<Burst width< 200us: ±10%;

    0.5us<Burst width< 1us: ±15%;

    Burst width< 0.5us: ±20%;

    Peak Average Ratio

    0 to12dB

    CCDF

    Measurement Range

    0.1 to 100%

    Measurement Accuracy

    ±3%

    Threshold Measurement Range

    0.05W to 500W

    Burst Power

    Burst Power Range

    100mW to 200W

    Burst Width

    1us to 60ms

    Min. Measurement Frequency

    15Hz

    Measurement Accuracy

    ±6%

    Duty Cycle

    0.0001 to 1

    Others

    Power Supply

    USB

    Operating Temperature

    -10 to50

    Storage Temperature

    -20 to70

    Relative Humidity

    0 to 85% (Non-condensing)

    Weight

    0.48kg

    Dimensions (H×W×T)

    130××124×34mm


     * Specifications subject to change without notice

    Order Information:

    Standard Package:

    CAA-100 Host, Lithium Battery, AC Adapter, CD(PC Software, User Manual), Carrying Case, T-type Calibration Kits, Quick Reference

    Optional:

    ¨  TPM Module (Optional)--RF Terminal Power Meter

    ¨  SPM Module(Optional)--In Line Digital Frequency Spectrum Power Meter

    Test Cables

    o  1.5m, N(m)-N(f), DC to 6GHz, 50 Ohm

    o  1.5m, N(m)-N(m), DC to 6GHz, 50 Ohm

    o  1.5m, N(m)-7/16 DIN(f), DC to 6GHz, 50 Ohm

    o  1.5m, N(m)-7/16 DIN(m), DC to 6GHz, 50 Ohm

    o  3m, N(m)-N(f), DC to 6GHz, 50 Ohm

    o  3m, N(m)-N(m), DC to 6GHz, 50 Ohm

    Adapters

    o  SMA(m)-N(m), DC to 6GHz, 50 Ohm

    o  SMA(f)-N(m), DC to 6GHz, 50 Ohm

    o  SMA(m)-N(f), DC to 6GHz, 50 Ohm

    o  SMA(f)-N(f), DC to 6GHz, 50 Ohm

    o  BNC(f)-N(m), DC to 6GHz, 50 Ohm

    o  7/16 DIN(f)-N(m), DC to 6GHz, 50 Ohm

    o  7/16 DIN(f)-N(f), DC to 6GHz, 50 Ohm

    o  7/16 DIN(m)-N(m), DC to 6GHz, 50 Ohm

    o  7/16 DIN(m)-N(f), DC to 6GHz, 50 Ohm

    o  7/16 DIN(m)-7/16DIN(m), DC to 6GHz, 50 Ohm

    o  7/16 DIN(f)-7/16DIN(f), DC to 6GHz, 50 Ohm

    o  N(m)-N(m), DC to 6GHz, 50 Ohm

    o  N(f)-N(f), DC to 6GHz, 50 Ohm

    o  N(m) 50Ohm – N(f) 75OhmDC to 3GHz

    o  N(f) 50Ohm – N(m) 75OhmDC to 3GHz

    Calibrators

    o  T-type calibrator(OPEN-SHORT-50 Ohm), N(m), DC to 6GHz, 50 Ohm

    o  Calibrator Kit(OPEN×1, SHORT×1, 50 Ohm×1), N(m), DC to 6GHz, 50 Ohm

    o  OPEN Calibrator×1, N(m), DC to 6GHz

    o  SHORT Calibrator×1, N(m), DC to 6GHz

    o  50 Ohm Calibrator×1N(m), DC to 6GHz, 50 Ohm

All Products     |     Close