DWDM OTDR with Tunable Laser
MTP-200-D100
Multi-Function and High Performance OTDR Testing
● 96 C-band wavelengths
● Dynamic range up to 38dB
● Short zone: EDZ 1m, ADZ 4m
● Tunable laser source with 50GHz spacing
● Auto/manual test and analysis
● Multi-wavelength testing
● Visible laser source function
● Fault locating, fiber length/loss/return loss measurement, connector/ splice/ splitter/ macro bend/fiber-end detection
● GR-196-CORE (.SOR) file format
● SOR and JPG file format
● Flexible file naming
● LinkImage smart graphic analysis
Optimized Platform Performance
● Lightweight, 2.1kg
● 7 inch touch screen
● Windows user interface for easy operation
● Damp-dust-shock proof

● 10 hours continuous operation
● Supports WiFi / Bluetooth / GPS
● Direct printing function(compatible with PCL printers)
● Remote/local control by PC

MTP Suite PC Software
● Multi traces analysis
● Single/multi traces printing in one report
● Batch editing and printing
● Bidirectional traces analysis
● CSV report formats
● Remote control function

Network RemoteControl Module (Optional)
● Convenient networking
● Remote control instrument operation

Optical Power Meter Module (Optional)
● Focusing knob for fast focus
● Eye-safe and clear video viewing
● Interchangeable connector tips

ptical Power Meter Module (Optional)
● Multi-wavelength Calibration
● High Precision
● Convenient Operation

Applications
● DWDM network fiber characterization
● DWDM live testing
● Verification of ROADM channel routing
● Test through OADM and MUX/DMUX
| MTP-200 Series |
| Display |
7 inch TFT Touch Screen (800×480) |
| Connectivity |
USB×2; 10/100Mbit/s RJ-45×1 |
| Memory |
2GB |
| Power Supply |
Rechargeable Li-Ion Battery/AC Adapter |
| Battery Life |
10 hours continuous operation |
| Working Temp. |
-20°C - 50°C |
| Storage Temp. |
-40°C - 60°C |
| Humidity |
0 - 95% (Non-Condensing) |
| Weight |
2.1kg |
| Dimensions (L×W×H ) |
290×175×75mm |
| OTDR Module |
Wavelength |
| MTP-200-D100 |
1528.77-1566.72nm @ 0.4nm Spacing |
| Dynamic Range(1) |
38dB |
| Dead Zone(2) |
EDZ: 1m, ADZ: 4m |
| Selectable Range |
SM: 1.3, 2.5, 5, 10, 20, 40, 80, 160, 240Km |
| Pulse Width |
SM: 5ns,10ns, 30ns, 100ns, 300ns,1µs, 2.5µs,10µs, 20µs |
| Sampling Points |
256000 |
| Averaging Time |
Quick, 15s, 30s, 45s, 60s, 90s, 120s, 180s |
| Connector |
FC/PC (Interchangeable SC, ST and LC ) |
| Distance Accuracy |
±(1m + 5x10-5 x distance +sampling resolution) |
| Attenuation Accuracy |
±0.05 dB/dB |
| Reflection Accuracy |
±4 dB |
| Visible Laser Source |
Output Power: ≥ -3dBm |
MOD Frequency: 1Hz |
Detecting Range: 5Km |
| Tunable Laser Source |
| Frequency Range |
191 - 196 THz |
| Wavelength Range |
1528-1566nm |
| Accuracy |
2.5 GHz |
| Line Width |
10 MHz |
| SMSR |
40 dB |
| Output Power Range |
+9 dBm to +13 dBm (C Band) |
| Power Setting Resolution |
0.01 dB |
| Power Variation over Wavelength Range |
±0.5 dB |
| Minimum Channel Spacing |
50 GHz (0.4nm) |
| Reflection Accuracy |
±4 dB |
| Relative Intensity Noise |
-140 dB/Hz |
| MCI100 Optical Connector Inspector Module (Optional) |
| Field of View |
400µm×300µm |
| Resolution |
≤1.5µm |
| Focusing |
Manual Focus |
| Microscope Dimensions |
Ø32×175mm |
| PM100 Normal Power Meter Module (Optional) |
| Calibrated Wavelength |
850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm, 1650nm |
| Measurement Range |
-70dBm - +6dBm (-60dBm - +6dBm @ 850nm) |
| Detector Type |
InGaAs |
| Display Resolution |
0.01dB |
| Accuracy |
± 5% ± 0.01nW (±0.5dB@850nm) |
*Specifications subject to change without notice
Notes
(1) Dynamic range measurement at 20µs pulse width and 180s averaging time;
(2) Dead Zone measurement at 0.6Km and reflection <-45dB; EDZ measurement at 5ns, ADZ measurement at 10ns.
Order Information:
Standard Package
MTP-200, Lithium Battery, CD (User’s Manual and MTP Suite Software), Carrying Case, Warranty card, Calibration Certificate
Optional Modules:
PM100: Optical Power Meter Module MCI100: Optical Connector Inspector Module RC100: Remote control Module
LM100: Link Image Module